// HDC1080 / 831R Sensor over I2C
|
|
// Based on SI7021 / HTU21D Sensor over I2C
|
|
// Copyright (C) 2017-2019 by Xose Pérez <xose dot perez at gmail dot com>
|
|
// Copyright (C) 2020 by Alexander Kolesnikov <vtochq at gmail dot com>
|
|
// -----------------------------------------------------------------------------
|
|
|
|
#if SENSOR_SUPPORT && HDC1080_SUPPORT
|
|
|
|
#pragma once
|
|
|
|
|
|
#include "I2CSensor.h"
|
|
#include "../utils.h"
|
|
|
|
#define HDC1080_SCL_FREQUENCY 200
|
|
|
|
// ref. http://www.ti.com/lit/ds/symlink/hdc1080.pdf
|
|
// Device ID. Should be the same for every device.
|
|
#define HDC1080_DEVICE_ID 0x1050
|
|
|
|
#define HDC1080_CMD_TMP 0x00
|
|
#define HDC1080_CMD_HUM 0x01
|
|
|
|
class HDC1080Sensor : public I2CSensor<> {
|
|
|
|
public:
|
|
|
|
// ---------------------------------------------------------------------
|
|
// Sensor API
|
|
// ---------------------------------------------------------------------
|
|
|
|
unsigned char id() const override {
|
|
return SENSOR_HDC1080_ID;
|
|
}
|
|
|
|
unsigned char count() const override {
|
|
return 2;
|
|
}
|
|
|
|
// Initialization method, must be idempotent
|
|
void begin() override {
|
|
if (!_dirty) return;
|
|
_init();
|
|
_dirty = !_ready;
|
|
}
|
|
|
|
// Descriptive name of the sensor
|
|
String description() const override {
|
|
char buffer[25];
|
|
snprintf_P(buffer, sizeof(buffer),
|
|
PSTR("HDC1080 @ I2C (0x%02X)"), lockedAddress());
|
|
return String(buffer);
|
|
}
|
|
|
|
// Descriptive name of the slot # index
|
|
String description(unsigned char) const override {
|
|
return description();
|
|
};
|
|
|
|
// Type for slot # index
|
|
unsigned char type(unsigned char index) const override {
|
|
if (index == 0) return MAGNITUDE_TEMPERATURE;
|
|
if (index == 1) return MAGNITUDE_HUMIDITY;
|
|
return MAGNITUDE_NONE;
|
|
}
|
|
|
|
// Pre-read hook (usually to populate registers with up-to-date data)
|
|
void pre() override {
|
|
_error = SENSOR_ERROR_OK;
|
|
|
|
const auto address = lockedAddress();
|
|
double value = _read(address, HDC1080_CMD_TMP);
|
|
if (_error != SENSOR_ERROR_OK) {
|
|
return;
|
|
}
|
|
|
|
_temperature = (165 * value / 65536) - 40;
|
|
|
|
value = _read(address, HDC1080_CMD_HUM);
|
|
if (_error != SENSOR_ERROR_OK) {
|
|
return;
|
|
}
|
|
|
|
value = (value / 65536) * 100;
|
|
_humidity = std::clamp(value, 0.0, 100.0);
|
|
}
|
|
|
|
// Current value for slot # index
|
|
double value(unsigned char index) override {
|
|
if (index == 0) return _temperature;
|
|
if (index == 1) return _humidity;
|
|
return 0;
|
|
}
|
|
|
|
protected:
|
|
|
|
// ---------------------------------------------------------------------
|
|
// Protected
|
|
// ---------------------------------------------------------------------
|
|
|
|
void _init() {
|
|
|
|
// I2C auto-discover
|
|
static constexpr uint8_t addresses[] {0x40};
|
|
auto address = findAndLock(addresses);
|
|
if (address == 0) {
|
|
return;
|
|
}
|
|
|
|
// Check device ID before doing anything else
|
|
// ref. https://github.com/xoseperez/espurna/issues/2270#issuecomment-639239944
|
|
// > Also there are clones of HDC1080 and they may have different Device ID
|
|
// > values. You need to check it by reading and debug output this bytes.
|
|
i2c_write_uint8(address, 0xFF);
|
|
_device_id = i2c_read_uint16(address);
|
|
|
|
if (_device_id != HDC1080_DEVICE_ID) {
|
|
DEBUG_MSG_P(PSTR("[HDC1080] ERROR: Expected Device ID 0x%04X, received 0x%04X\n"),
|
|
HDC1080_DEVICE_ID, _device_id);
|
|
_ready = false;
|
|
resetUnknown();
|
|
return;
|
|
}
|
|
|
|
_ready = true;
|
|
}
|
|
|
|
unsigned int _read(uint8_t address, uint8_t command) {
|
|
|
|
// Request measurement
|
|
i2c_write_uint8(address, command);
|
|
|
|
// When not using clock stretching (*_NOHOLD commands) delay here
|
|
// is needed to wait for the measurement.
|
|
// According to datasheet the max. conversion time is ~22ms
|
|
espurna::time::blockingDelay(
|
|
espurna::duration::Milliseconds(50));
|
|
|
|
// Clear the last to bits of LSB to 00.
|
|
// According to datasheet LSB of Temp and RH is always xxxxxx00
|
|
unsigned int value = i2c_read_uint16(address) & 0xFFFC;
|
|
|
|
// We should be checking there are no pending bytes in the buffer
|
|
// and raise a CRC error if there are
|
|
_error = SENSOR_ERROR_OK;
|
|
|
|
return value;
|
|
|
|
}
|
|
|
|
uint16_t _device_id = 0;
|
|
double _temperature = 0;
|
|
double _humidity = 0;
|
|
|
|
};
|
|
|
|
#endif // SENSOR_SUPPORT && HDC1080_SUPPORT
|