- POW MODULE
- Support for Sonoff POW HLW8012-based power monitor
-
- Copyright (C) 2016-2017 by Xose Pérez <xose dot perez at gmail dot com>
-
- */
-
- #if ENABLE_POW
-
- #include <HLW8012.h>
- #include <Hash.h>
- #include <ArduinoJson.h>
-
- HLW8012 hlw8012;
- bool _powEnabled = false;
-
- // -----------------------------------------------------------------------------
- // POW
- // -----------------------------------------------------------------------------
-
- // When using interrupts we have to call the library entry point
- // whenever an interrupt is triggered
- void hlw8012_cf1_interrupt() {
- hlw8012.cf1_interrupt();
- }
-
- void hlw8012_cf_interrupt() {
- hlw8012.cf_interrupt();
- }
-
- void powEnable(bool status) {
- _powEnabled = status;
- if (_powEnabled) {
- #if POW_USE_INTERRUPTS == 1
- attachInterrupt(POW_CF1_PIN, hlw8012_cf1_interrupt, CHANGE);
- attachInterrupt(POW_CF_PIN, hlw8012_cf_interrupt, CHANGE);
- #endif
- DEBUG_MSG("[POW] Enabled\n");
- } else {
- #if POW_USE_INTERRUPTS == 1
- detachInterrupt(POW_CF1_PIN);
- detachInterrupt(POW_CF_PIN);
- #endif
- DEBUG_MSG("[POW] Disabled\n");
- }
- }
-
- // -----------------------------------------------------------------------------
-
- void powSaveCalibration() {
- setSetting("powPowerMult", hlw8012.getPowerMultiplier());
- setSetting("powCurrentMult", hlw8012.getCurrentMultiplier());
- setSetting("powVoltageMult", hlw8012.getVoltageMultiplier());
- }
-
- void powRetrieveCalibration() {
- double value;
- value = getSetting("powPowerMult", 0).toFloat();
- if (value > 0) hlw8012.setPowerMultiplier((int) value);
- value = getSetting("powCurrentMult", 0).toFloat();
- if (value > 0) hlw8012.setCurrentMultiplier((int) value);
- value = getSetting("powVoltageMult", 0).toFloat();
- if (value > 0) hlw8012.setVoltageMultiplier((int) value);
- }
-
- void powSetExpectedActivePower(unsigned int power) {
- if (power > 0) {
- hlw8012.expectedActivePower(power);
- powSaveCalibration();
- }
- }
-
- void powSetExpectedCurrent(double current) {
- if (current > 0) {
- hlw8012.expectedCurrent(current);
- powSaveCalibration();
- }
- }
-
- void powSetExpectedVoltage(unsigned int voltage) {
- if (voltage > 0) {
- hlw8012.expectedVoltage(voltage);
- powSaveCalibration();
- }
- }
-
- void powReset() {
- hlw8012.resetMultipliers();
- powSaveCalibration();
- }
-
- // -----------------------------------------------------------------------------
-
- unsigned int getActivePower() {
- return hlw8012.getActivePower();
- }
-
- unsigned int getApparentPower() {
- return hlw8012.getApparentPower();
- }
-
- unsigned int getReactivePower() {
- return hlw8012.getReactivePower();
- }
-
- double getCurrent() {
- return hlw8012.getCurrent();
- }
-
- unsigned int getVoltage() {
- return hlw8012.getVoltage();
- }
-
- unsigned int getPowerFactor() {
- return (int) (100 * hlw8012.getPowerFactor());
- }
-
- // -----------------------------------------------------------------------------
-
- void powSetup() {
-
- // Initialize HLW8012
- // void begin(unsigned char cf_pin, unsigned char cf1_pin, unsigned char sel_pin, unsigned char currentWhen = HIGH, bool use_interrupts = false, unsigned long pulse_timeout = PULSE_TIMEOUT);
- // * cf_pin, cf1_pin and sel_pin are GPIOs to the HLW8012 IC
- // * currentWhen is the value in sel_pin to select current sampling
- // * set use_interrupts to true to use interrupts to monitor pulse widths
- // * leave pulse_timeout to the default value, recommended when using interrupts
- #if POW_USE_INTERRUPTS
- hlw8012.begin(POW_CF_PIN, POW_CF1_PIN, POW_SEL_PIN, POW_SEL_CURRENT, true);
- #else
- hlw8012.begin(POW_CF_PIN, POW_CF1_PIN, POW_SEL_PIN, POW_SEL_CURRENT, false, 1000000);
- #endif
-
- // These values are used to calculate current, voltage and power factors as per datasheet formula
- // These are the nominal values for the Sonoff POW resistors:
- // * The CURRENT_RESISTOR is the 1milliOhm copper-manganese resistor in series with the main line
- // * The VOLTAGE_RESISTOR_UPSTREAM are the 5 470kOhm resistors in the voltage divider that feeds the V2P pin in the HLW8012
- // * The VOLTAGE_RESISTOR_DOWNSTREAM is the 1kOhm resistor in the voltage divider that feeds the V2P pin in the HLW8012
- hlw8012.setResistors(POW_CURRENT_R, POW_VOLTAGE_R_UP, POW_VOLTAGE_R_DOWN);
-
- // Retrieve calibration values
- powRetrieveCalibration();
-
- // API definitions
- apiRegister("/api/power", "power", [](char * buffer, size_t len) {
- snprintf(buffer, len, "%d", getActivePower());
- });
- apiRegister("/api/current", "current", [](char * buffer, size_t len) {
- dtostrf(getCurrent(), len-1, 2, buffer);
- });
- apiRegister("/api/voltage", "voltage", [](char * buffer, size_t len) {
- snprintf(buffer, len, "%d", getVoltage());
- });
-
- }
-
- void powLoop() {
-
- static unsigned long last_update = 0;
- static unsigned char report_count = POW_REPORT_EVERY;
-
- static unsigned long power_sum = 0;
- static double current_sum = 0;
- static unsigned long voltage_sum = 0;
- static bool powWasEnabled = false;
-
- // POW is disabled while there is no internet connection
- // When the HLW8012 measurements are enabled back we reset the timer
- if (!_powEnabled) {
- powWasEnabled = false;
- return;
- }
- if (!powWasEnabled) {
- last_update = millis();
- powWasEnabled = true;
- }
-
- if (millis() - last_update > POW_UPDATE_INTERVAL) {
-
- last_update = millis();
-
- unsigned int power = getActivePower();
- unsigned int voltage = getVoltage();
- double current = getCurrent();
- unsigned int apparent = getApparentPower();
- unsigned int factor = getPowerFactor();
- unsigned int reactive = getReactivePower();
-
- power_sum += power;
- current_sum += current;
- voltage_sum += voltage;
-
- DynamicJsonBuffer jsonBuffer;
- JsonObject& root = jsonBuffer.createObject();
-
- root["powVisible"] = 1;
- root["powActivePower"] = power;
- root["powCurrent"] = current;
- root["powVoltage"] = voltage;
- root["powApparentPower"] = apparent;
- root["powReactivePower"] = reactive;
- root["powPowerFactor"] = factor;
-
- String output;
- root.printTo(output);
- wsSend(output.c_str());
-
- if (--report_count == 0) {
-
- power = power_sum / POW_REPORT_EVERY;
- current = current_sum / POW_REPORT_EVERY;
- voltage = voltage_sum / POW_REPORT_EVERY;
- apparent = current * voltage;
- reactive = (apparent > power) ? sqrt(apparent * apparent - power * power) : 0;
- factor = (apparent > 0) ? 100 * power / apparent : 100;
- if (factor > 100) factor = 100;
-
- mqttSend(getSetting("powPowerTopic", POW_POWER_TOPIC).c_str(), String(power).c_str());
- mqttSend(getSetting("powCurrentTopic", POW_CURRENT_TOPIC).c_str(), String(current).c_str());
- mqttSend(getSetting("powVoltageTopic", POW_VOLTAGE_TOPIC).c_str(), String(voltage).c_str());
- mqttSend(getSetting("powAPowerTopic", POW_APOWER_TOPIC).c_str(), String(apparent).c_str());
- mqttSend(getSetting("powRPowerTopic", POW_RPOWER_TOPIC).c_str(), String(reactive).c_str());
- mqttSend(getSetting("powPFactorTopic", POW_PFACTOR_TOPIC).c_str(), String(factor).c_str());
-
- #if ENABLE_DOMOTICZ
- domoticzSend("dczPowIdx", power);
- #endif
-
- power_sum = current_sum = voltage_sum = 0;
- report_count = POW_REPORT_EVERY;
-
- }
-
- // Toggle between current and voltage monitoring
- #if POW_USE_INTERRUPTS == 0
- hlw8012.toggleMode();
- #endif
-
- }
-
- }
-
- #endif
|