- POW MODULE
- Support for Sonoff POW HLW8012-based power monitor
-
- Copyright (C) 2016-2017 by Xose Pérez <xose dot perez at gmail dot com>
-
- */
-
- #if HLW8012_SUPPORT
-
- #include <HLW8012.h>
- #include <Hash.h>
- #include <ArduinoJson.h>
-
- HLW8012 hlw8012;
- bool _hlw8012Enabled = false;
- bool _hlwReady = false;
- int _hlwPower = 0;
- double _hlwCurrent = 0;
- int _hlwVoltage = 0;
-
- // -----------------------------------------------------------------------------
- // POW
- // -----------------------------------------------------------------------------
-
- // When using interrupts we have to call the library entry point
- // whenever an interrupt is triggered
- void ICACHE_RAM_ATTR hlw8012_cf1_interrupt() {
- hlw8012.cf1_interrupt();
- }
-
- void ICACHE_RAM_ATTR hlw8012_cf_interrupt() {
- hlw8012.cf_interrupt();
- }
-
- void hlw8012Enable(bool status) {
- _hlw8012Enabled = status;
- if (_hlw8012Enabled) {
- #if HLW8012_USE_INTERRUPTS == 1
- attachInterrupt(HLW8012_CF1_PIN, hlw8012_cf1_interrupt, CHANGE);
- attachInterrupt(HLW8012_CF_PIN, hlw8012_cf_interrupt, CHANGE);
- #endif
- DEBUG_MSG_P(PSTR("[POW] Enabled\n"));
- } else {
- #if HLW8012_USE_INTERRUPTS == 1
- detachInterrupt(HLW8012_CF1_PIN);
- detachInterrupt(HLW8012_CF_PIN);
- #endif
- DEBUG_MSG_P(PSTR("[POW] Disabled\n"));
- }
- }
-
- // -----------------------------------------------------------------------------
-
- void hlw8012SaveCalibration() {
- setSetting("powPowerMult", hlw8012.getPowerMultiplier());
- setSetting("powCurrentMult", hlw8012.getCurrentMultiplier());
- setSetting("powVoltageMult", hlw8012.getVoltageMultiplier());
- saveSettings();
- }
-
- void hlw8012RetrieveCalibration() {
- double value;
- value = getSetting("powPowerMult", 0).toFloat();
- if (value > 0) hlw8012.setPowerMultiplier(value);
- value = getSetting("powCurrentMult", 0).toFloat();
- if (value > 0) hlw8012.setCurrentMultiplier(value);
- value = getSetting("powVoltageMult", 0).toFloat();
- if (value > 0) hlw8012.setVoltageMultiplier(value);
- }
-
- void hlw8012SetExpectedActivePower(unsigned int power) {
- if (power > 0) {
- hlw8012.expectedActivePower(power);
- hlw8012SaveCalibration();
- }
- }
-
- void hlw8012SetExpectedCurrent(double current) {
- if (current > 0) {
- hlw8012.expectedCurrent(current);
- hlw8012SaveCalibration();
- }
- }
-
- void hlw8012SetExpectedVoltage(unsigned int voltage) {
- if (voltage > 0) {
- hlw8012.expectedVoltage(voltage);
- hlw8012SaveCalibration();
- }
- }
-
- void hlw8012Reset() {
- hlw8012.resetMultipliers();
- hlw8012SaveCalibration();
- }
-
- // -----------------------------------------------------------------------------
- // HAL
- // -----------------------------------------------------------------------------
-
- unsigned int getActivePower() {
- unsigned int power = hlw8012.getActivePower();
- if (HLW8012_MIN_POWER > power || power > HLW8012_MAX_POWER) power = 0;
- return power;
- }
-
- unsigned int getApparentPower() {
- unsigned int power = hlw8012.getApparentPower();
- if (HLW8012_MIN_POWER > power || power > HLW8012_MAX_POWER) power = 0;
- return power;
- }
-
- unsigned int getReactivePower() {
- unsigned int power = hlw8012.getReactivePower();
- if (HLW8012_MIN_POWER > power || power > HLW8012_MAX_POWER) power = 0;
- return power;
- }
-
- double getCurrent() {
- double current = hlw8012.getCurrent();
- if (HLW8012_MIN_CURRENT > current || current > HLW8012_MAX_CURRENT) current = 0;
- return current;
- }
-
- unsigned int getVoltage() {
- return hlw8012.getVoltage();
- }
-
- double getPowerFactor() {
- return hlw8012.getPowerFactor();
- }
-
- // -----------------------------------------------------------------------------
-
- void hlw8012Setup() {
-
- // Initialize HLW8012
- // void begin(unsigned char cf_pin, unsigned char cf1_pin, unsigned char sel_pin, unsigned char currentWhen = HIGH, bool use_interrupts = false, unsigned long pulse_timeout = PULSE_TIMEOUT);
- // * cf_pin, cf1_pin and sel_pin are GPIOs to the HLW8012 IC
- // * currentWhen is the value in sel_pin to select current sampling
- // * set use_interrupts to true to use interrupts to monitor pulse widths
- // * leave pulse_timeout to the default value, recommended when using interrupts
- #if HLW8012_USE_INTERRUPTS
- hlw8012.begin(HLW8012_CF_PIN, HLW8012_CF1_PIN, HLW8012_SEL_PIN, HLW8012_SEL_CURRENT, true);
- #else
- hlw8012.begin(HLW8012_CF_PIN, HLW8012_CF1_PIN, HLW8012_SEL_PIN, HLW8012_SEL_CURRENT, false, 1000000);
- #endif
-
- // These values are used to calculate current, voltage and power factors as per datasheet formula
- // These are the nominal values for the Sonoff POW resistors:
- // * The CURRENT_RESISTOR is the 1milliOhm copper-manganese resistor in series with the main line
- // * The VOLTAGE_RESISTOR_UPSTREAM are the 5 470kOhm resistors in the voltage divider that feeds the V2P pin in the HLW8012
- // * The VOLTAGE_RESISTOR_DOWNSTREAM is the 1kOhm resistor in the voltage divider that feeds the V2P pin in the HLW8012
- hlw8012.setResistors(HLW8012_CURRENT_R, HLW8012_VOLTAGE_R_UP, HLW8012_VOLTAGE_R_DOWN);
-
- // Retrieve calibration values
- hlw8012RetrieveCalibration();
-
- // API definitions
- #if WEB_SUPPORT
-
- apiRegister(HLW8012_POWER_TOPIC, HLW8012_POWER_TOPIC, [](char * buffer, size_t len) {
- if (_hlwReady) {
- snprintf_P(buffer, len, PSTR("%d"), _hlwPower);
- } else {
- buffer = NULL;
- }
- });
- apiRegister(HLW8012_CURRENT_TOPIC, HLW8012_CURRENT_TOPIC, [](char * buffer, size_t len) {
- if (_hlwReady) {
- dtostrf(_hlwCurrent, len-1, 3, buffer);
- } else {
- buffer = NULL;
- }
- });
- apiRegister(HLW8012_VOLTAGE_TOPIC, HLW8012_VOLTAGE_TOPIC, [](char * buffer, size_t len) {
- if (_hlwReady) {
- snprintf_P(buffer, len, PSTR("%d"), _hlwVoltage);
- } else {
- buffer = NULL;
- }
- });
-
- #endif // WEB_SUPPORT
-
- }
-
- void hlw8012Loop() {
-
- static unsigned long last_update = 0;
- static unsigned char report_count = HLW8012_REPORT_EVERY;
-
- static bool power_spike = false;
- static unsigned long power_sum = 0;
- static unsigned long power_previous = 0;
-
- static bool current_spike = false;
- static double current_sum = 0;
- static double current_previous = 0;
-
- static bool voltage_spike = false;
- static unsigned long voltage_sum = 0;
- static unsigned long voltage_previous = 0;
-
- static bool powWasEnabled = false;
-
- // POW is disabled while there is no internet connection
- // When the HLW8012 measurements are enabled back we reset the timer
- if (!_hlw8012Enabled) {
- powWasEnabled = false;
- return;
- }
- if (!powWasEnabled) {
- last_update = millis();
- powWasEnabled = true;
- }
-
- if (millis() - last_update > HLW8012_UPDATE_INTERVAL) {
-
- last_update = millis();
-
- unsigned int power = getActivePower();
- unsigned int voltage = getVoltage();
- double current = getCurrent();
-
- if (power > 0) {
- power_spike = (power_previous == 0);
- } else if (power_spike) {
- power_sum -= power_previous;
- power_spike = false;
- }
- power_previous = power;
-
- if (current > 0) {
- current_spike = (current_previous == 0);
- } else if (current_spike) {
- current_sum -= current_previous;
- current_spike = false;
- }
- current_previous = current;
-
- if (voltage > 0) {
- voltage_spike = (voltage_previous == 0);
- } else if (voltage_spike) {
- voltage_sum -= voltage_previous;
- voltage_spike = false;
- }
- voltage_previous = voltage;
-
- #if WEB_SUPPORT
- {
- unsigned int apparent = getApparentPower();
- double factor = getPowerFactor();
- unsigned int reactive = getReactivePower();
-
- DynamicJsonBuffer jsonBuffer;
- JsonObject& root = jsonBuffer.createObject();
-
- root["powVisible"] = 1;
- root["powActivePower"] = power;
- root["powCurrent"] = String(current, 3);
- root["powVoltage"] = voltage;
- root["powApparentPower"] = apparent;
- root["powReactivePower"] = reactive;
- root["powPowerFactor"] = String(factor, 2);
-
- String output;
- root.printTo(output);
- wsSend(output.c_str());
- }
- #endif
-
- if (--report_count == 0) {
-
- // Update globals
- _hlwPower = power_sum / HLW8012_REPORT_EVERY;
- _hlwCurrent = current_sum / HLW8012_REPORT_EVERY;
- _hlwVoltage = voltage_sum / HLW8012_REPORT_EVERY;
- _hlwReady = true;
-
- // Calculate subproducts (apparent and reactive power, power factor and delta energy)
- unsigned int apparent = _hlwCurrent * _hlwVoltage;
- unsigned int reactive = (apparent > _hlwPower) ? sqrt(apparent * apparent - _hlwPower * _hlwPower) : 0;
- double factor = (apparent > 0) ? (double) _hlwPower / apparent : 1;
- if (factor > 1) factor = 1;
- double energy_delta = (double) _hlwPower * HLW8012_REPORT_EVERY * HLW8012_UPDATE_INTERVAL / 1000.0 / 3600.0;
-
- // Report values to MQTT broker
- mqttSend(getSetting("powPowerTopic", HLW8012_POWER_TOPIC).c_str(), String(_hlwPower).c_str());
- mqttSend(getSetting("powCurrentTopic", HLW8012_CURRENT_TOPIC).c_str(), String(_hlwCurrent, 3).c_str());
- mqttSend(getSetting("powVoltageTopic", HLW8012_VOLTAGE_TOPIC).c_str(), String(_hlwVoltage).c_str());
- mqttSend(getSetting("powEnergyTopic", HLW8012_ENERGY_TOPIC).c_str(), String(energy_delta, 3).c_str());
- mqttSend(getSetting("powAPowerTopic", HLW8012_APOWER_TOPIC).c_str(), String(apparent).c_str());
- mqttSend(getSetting("powRPowerTopic", HLW8012_RPOWER_TOPIC).c_str(), String(reactive).c_str());
- mqttSend(getSetting("powPFactorTopic", HLW8012_PFACTOR_TOPIC).c_str(), String(factor, 2).c_str());
-
- // Report values to Domoticz
- #if DOMOTICZ_SUPPORT
- {
- char buffer[20];
- snprintf_P(buffer, sizeof(buffer), PSTR("%d;%s"), _hlwPower, String(energy_delta, 3).c_str());
- domoticzSend("dczPowIdx", 0, buffer);
- snprintf_P(buffer, sizeof(buffer), PSTR("%s"), String(energy_delta, 3).c_str());
- domoticzSend("dczEnergyIdx", 0, buffer);
- snprintf_P(buffer, sizeof(buffer), PSTR("%d"), _hlwVoltage);
- domoticzSend("dczVoltIdx", 0, buffer);
- snprintf_P(buffer, sizeof(buffer), PSTR("%s"), String(_hlwCurrent).c_str());
- domoticzSend("dczCurrentIdx", 0, buffer);
- }
- #endif
-
- #if INFLUXDB_SUPPORT
- influxDBSend(getSetting("powPowerTopic", HLW8012_POWER_TOPIC).c_str(), String(_hlwPower).c_str());
- influxDBSend(getSetting("powCurrentTopic", HLW8012_CURRENT_TOPIC).c_str(), String(_hlwCurrent, 3).c_str());
- influxDBSend(getSetting("powVoltageTopic", HLW8012_VOLTAGE_TOPIC).c_str(), String(_hlwVoltage).c_str());
- influxDBSend(getSetting("powEnergyTopic", HLW8012_ENERGY_TOPIC).c_str(), String(energy_delta, 3).c_str());
- influxDBSend(getSetting("powAPowerTopic", HLW8012_APOWER_TOPIC).c_str(), String(apparent).c_str());
- influxDBSend(getSetting("powRPowerTopic", HLW8012_RPOWER_TOPIC).c_str(), String(reactive).c_str());
- influxDBSend(getSetting("powPFactorTopic", HLW8012_PFACTOR_TOPIC).c_str(), String(factor, 2).c_str());
- #endif
-
- // Reset counters
- power_sum = current_sum = voltage_sum = 0;
- report_count = HLW8012_REPORT_EVERY;
-
- }
-
- // Post - Accumulators
- power_sum += power_previous;
- current_sum += current_previous;
- voltage_sum += voltage_previous;
-
- // Toggle between current and voltage monitoring
- #if HLW8012_USE_INTERRUPTS == 0
- hlw8012.toggleMode();
- #endif
-
- }
-
- }
-
- #endif
|