- Update sensor classes to support a generic way to store energy values
- Update sensor conversion code to deal with units and not magnitudes
- Add magnitude<->unit for sensors, generic way of defining used unit. Convert from sensor magnitude unit to the one used for display.
- Reset energy value based on index through external means (MQTT, HTTP)
- Rework energy timestamping, update webui with 'last saved' value
While this solves the energy conversion issues and we are finally seeing the real value, what I don't really like:
- KilowattHour and WattHour are separate enum tags, thus sort-of are different types altogether
- Conversion code in Energy object should probably use some generic 'ratio' calculation? (https://en.cppreference.com/w/cpp/numeric/ratio/ratio)
- We are still using runtime checks to do calculations and depend that sensor outputs only one specific value type.
Consider this a fix for energy display / storage and preliminary work on sensor.ino
Further sensor refactoring... soon.
* gpio: detect esp8285 chip to allow the use of GPIO9 and GPIO10
* add another reference to the current rtos headers (but not used anywhere in the sdk code)
* fix typo in register order
* fixup! fix typo in register order