// HDC1080 / 831R Sensor over I2C
|
|
// Based on SI7021 / HTU21D Sensor over I2C
|
|
// Copyright (C) 2017-2019 by Xose Pérez <xose dot perez at gmail dot com>
|
|
// Copyright (C) 2020 by Alexander Kolesnikov <vtochq at gmail dot com>
|
|
// -----------------------------------------------------------------------------
|
|
|
|
#if SENSOR_SUPPORT && HDC1080_SUPPORT
|
|
|
|
#pragma once
|
|
|
|
#include <Arduino.h>
|
|
|
|
#include "I2CSensor.h"
|
|
#include "../utils.h"
|
|
|
|
#define HDC1080_SCL_FREQUENCY 200
|
|
|
|
// ref. http://www.ti.com/lit/ds/symlink/hdc1080.pdf
|
|
// Device ID. Should be the same for every device.
|
|
#define HDC1080_DEVICE_ID 0x1050
|
|
|
|
#define HDC1080_CMD_TMP 0x00
|
|
#define HDC1080_CMD_HUM 0x01
|
|
|
|
class HDC1080Sensor : public I2CSensor<> {
|
|
|
|
public:
|
|
|
|
// ---------------------------------------------------------------------
|
|
// Public
|
|
// ---------------------------------------------------------------------
|
|
|
|
HDC1080Sensor() {
|
|
_sensor_id = SENSOR_HDC1080_ID;
|
|
}
|
|
|
|
// ---------------------------------------------------------------------
|
|
// Sensor API
|
|
// ---------------------------------------------------------------------
|
|
|
|
// Initialization method, must be idempotent
|
|
void begin() {
|
|
if (!_dirty) return;
|
|
_init();
|
|
_dirty = !_ready;
|
|
}
|
|
|
|
// Descriptive name of the sensor
|
|
String description() {
|
|
char buffer[25];
|
|
snprintf_P(buffer, sizeof(buffer), PSTR("HDC1080 @ I2C (0x%02X)"), _address);
|
|
return String(buffer);
|
|
}
|
|
|
|
// Descriptive name of the slot # index
|
|
String description(unsigned char index) {
|
|
return description();
|
|
};
|
|
|
|
// Type for slot # index
|
|
unsigned char type(unsigned char index) {
|
|
if (index == 0) return MAGNITUDE_TEMPERATURE;
|
|
if (index == 1) return MAGNITUDE_HUMIDITY;
|
|
return MAGNITUDE_NONE;
|
|
}
|
|
|
|
// Pre-read hook (usually to populate registers with up-to-date data)
|
|
void pre() {
|
|
_error = SENSOR_ERROR_OK;
|
|
|
|
double value;
|
|
|
|
value = _read(HDC1080_CMD_TMP);
|
|
if (_error != SENSOR_ERROR_OK) return;
|
|
_temperature = (165 * value / 65536) - 40;
|
|
|
|
value = _read(HDC1080_CMD_HUM);
|
|
if (_error != SENSOR_ERROR_OK) return;
|
|
value = (value / 65536)*100;
|
|
_humidity = constrain(value, 0, 100);
|
|
}
|
|
|
|
// Current value for slot # index
|
|
double value(unsigned char index) {
|
|
if (index == 0) return _temperature;
|
|
if (index == 1) return _humidity;
|
|
return 0;
|
|
}
|
|
|
|
protected:
|
|
|
|
// ---------------------------------------------------------------------
|
|
// Protected
|
|
// ---------------------------------------------------------------------
|
|
|
|
void _init() {
|
|
|
|
// I2C auto-discover
|
|
unsigned char addresses[] = {0x40};
|
|
_address = _begin_i2c(_address, sizeof(addresses), addresses);
|
|
if (_address == 0) return;
|
|
|
|
// Check device ID before doing anything else
|
|
// ref. https://github.com/xoseperez/espurna/issues/2270#issuecomment-639239944
|
|
// > Also there are clones of HDC1080 and they may have different Device ID
|
|
// > values. You need to check it by reading and debug output this bytes.
|
|
i2c_write_uint8(_address, 0xFF);
|
|
_device_id = i2c_read_uint16(_address);
|
|
|
|
if (_device_id == HDC1080_DEVICE_ID) {
|
|
_ready = true;
|
|
_count = 2;
|
|
return;
|
|
}
|
|
|
|
DEBUG_MSG_P(PSTR("[HDC1080] ERROR: Expected Device ID %04X, received %04X\n"), HDC1080_DEVICE_ID, _device_id);
|
|
|
|
_count = 0;
|
|
i2cReleaseLock(_address);
|
|
_previous_address = 0;
|
|
_error = SENSOR_ERROR_UNKNOWN_ID;
|
|
|
|
// Setting _address to 0 forces auto-discover
|
|
// This might be necessary at this stage if there is a
|
|
// different sensor in the hardcoded address
|
|
_address = 0;
|
|
_ready = false;
|
|
|
|
}
|
|
|
|
unsigned int _read(uint8_t command) {
|
|
|
|
// Request measurement
|
|
i2c_write_uint8(_address, command);
|
|
|
|
// When not using clock stretching (*_NOHOLD commands) delay here
|
|
// is needed to wait for the measurement.
|
|
// According to datasheet the max. conversion time is ~22ms
|
|
nice_delay(50);
|
|
|
|
// Clear the last to bits of LSB to 00.
|
|
// According to datasheet LSB of Temp and RH is always xxxxxx00
|
|
unsigned int value = i2c_read_uint16(_address) & 0xFFFC;
|
|
|
|
// We should be checking there are no pending bytes in the buffer
|
|
// and raise a CRC error if there are
|
|
_error = SENSOR_ERROR_OK;
|
|
|
|
return value;
|
|
|
|
}
|
|
|
|
uint16_t _device_id = 0;
|
|
double _temperature = 0;
|
|
double _humidity = 0;
|
|
|
|
};
|
|
|
|
#endif // SENSOR_SUPPORT && HDC1080_SUPPORT
|